If thats not the air leak, check the pump lid o-ring, Superpump square lid rings sometimes get twisted easily. Check all the wire connections inside the motor on the terminal board, the 2 wires and the ground wire. Hi Tommy, very loud pump could be that the pump overheated, because it lost prime, and this either damaged the shaft bearings or melted/warped the impeller and diffuser. It wont respond to the controls at all. "@type": "ImageObject",
This is more of an indicator light than anything else. After 15-20 minutes, after cooling, the switch will close again, and the motor should restart. Oh, and prepare yourself, a new motor or pump may be needed soon. I have a Hayward super pump 1.5 hp. What happens when you switch the output to super-chlorinate? Better call an electrician for that though, 2 speed Hayward pool pump motor is very loud only when on high speed. If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. i have an in ground pool. Is there a trick to moving it to 115? This is my first pool. Hi Liane, a click coming from a control panel, could be a relay, clicking to send the signal to start the pump, but the signal is lost along the way. The heat sink is a ridged metal plate beneath the drive, that relies on air flow to help remove heat from the motor. The plastic shroud or cover over the impeller? Any suggestions. Hello there, if he customer wants to install a VS pump (required in 2021 for all new pumps), they could do that now. There is not much that can be done to increase flow rates for a smaller pump, with exception to reducing plumbing restrictions with larger pipe size and less elbows, etc. I have a problem when the heater warms up it blows bubbles/cloudy bubbles. My EC40 bump handle doesnt feel right. Sanitization, Learn About Any ideas? The ampage to the pump has been the same since we got the pump 7 years ago and never had this issue before. I dont want to pay someone to come out & charge me more for not knowing what Im doing. Step 3: Double check the wires on the flow switch for damage. Make sure that the fitting that goes into the pump has no air leaks, which is the most common air leak area. If it is cycling on/off (motor turning on/off) more rapidly, that would usually indicate loose wires, loose breaker, broken wires (sometimes inside the flexible conduit). Is that a result of all the water that got in the equipment during the storm? Before you test your capacitor, take note of its appearance. I turned it on and it ran fine for about one hour. I assume from your post that there are 2 possibilities 1) bad capacitor (I assume I can spot it visually) or 2) frozen shaft or propeller (how do I spot it and fix it? Display seems to be reading correctly and shows the cell is not generating. I have a new above ground pool with a Hayword pump. Just replaced the upper lid on my Vari-flow and spider gasket, also changed out 300 lbs filter sand. Flush out the housing to clear debris, then refill with water. Interesting however that you say the pump works on backwash, but not on filter? thanks. voltage reachs the stationary switch. They are cheap and easy to replace. I opened the back and was spinning the rod and it eventually started. We also a sense and dispense for pool chemistry that sometimes has a ph feeder timeout error code.could this have something to do with the pool pump running off the scheduled time? Greetings! Hi Jason, I would wait to spend the money, until certain that would be the fix. Chapter 1: The Evil Emperor's Son. Every time I vacuum my pool and then back wash and rinse. At this point, you can shut off power at the breaker, and pop the mechanism out of the box by depressing the tabs on the top, and inspect the gears and motor directly, for any insect problems, gecko tails (seen it!) HI Mike, the seal and the motor may be separate issues or they may be related. Hi Mary, flocculents usually produce a fluffy precipitate that is vacuumed to waste, because it clogs ups the filter. What does F5 mean? Yours may have become weak, or damaged somehow. The motor can be tested briefly without being bolted onto the pump. Could be a loose lid, or the basket not re-placed properly, and a clogged pump impeller. Check the pump lid o-ring or gasket, and be sure the lid is very tight. I have removed and tested the capacitor it appears OK I then removed the thermostat to try to access the shaft and turn it with a 7/17 wrench, but the protrusions on the casting and other spring mounted stuff appear to make it impossible to get a grip on the shaft. For more info, see page 36 of the Hayward heater owners manual. Looking for pool parts? 2. pump lid gasket or o-ring not lubed, or not positioned properly (superpump) Overheating pumps are usually DOA, in my experience, but there may be hope. Also check that the water level is high enough, and that a skimmer weir is not stuck in the up position, blocking water flow. Clean the filter cartridge well, allow it to dry fully, and then replace it back in the filter tank. Changed lid gasket and plugs in basket still same issue. Fourth, bad capacitor on the motor? What are some items I should check assy A for on the bench so I can possibly repair it? Do you know what the suggested torque is for the housing cap screws? If the clock motor is dead, you can replace just the motor, but most people replace the entire mechanism. Air leaks are another source of priming issues. Heat exchanger has to be getting too hot? $579 + Free Shipping in USA. Good day everyone. (I just bought the house and am new to pool upkeep.). Click here to shop our store. Hi, when my Hayward pool heater is on Im getting a sour odour from the exhaust. Hi Susan, hmm thats quite a conundrum! Just purchased a Hayward SP32002VSP. Search our blog for shaft seal replacement, if so. Pump shutoff during 24 hours of pouring rain. First, in regard to my Hayward pump basket lid, it is hard to turn counter clockwise, when i need to remove it but it does turn. I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. Unusual, but it could be the only problem, I would replace the capacitor with the same size (match the MFD number), and check that the shaft rotates freely when mounted to the pump. https://twitter.com/inyopoolsFOLLOW us on INSTAGRAM! If the No Flow LED is flashing, wait 60 seconds after starting your pump and filter. If so, you need stronger hose (or pipe), or add another suction pipe (and wall fitting). If you wire 110V to a 220V motor, it will not usually run, or will only slowly turn. A pool guy who has since stopped operating put it in. https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS the sound may possibly be a problem with the internal bypass, located in the front header. Next, maintain the proper salt levelin the pool. thanks. Home / Pool Equipment / Pool Heaters & Heat Pumps / Hayward Pool Heater Troubleshooting. Fingers crossed it is not that! I wonder if the lines are clogged or a pipe is partially collapsed. Hi, loud screeching sounds like bearings, yes. Using a circuit tester, I determined that the timer and the inline switch has power. If thats what is happening, then the cause of the overheating could be incorrect voltage or fluctuating voltage, incorrect wire size (from breaker or timer to motor), faulty wiring between some of the switches in the rear of the motor, or bad shaft bearings, or poor airflow or blocked air vents, or in some cases, very poor water flow. old. I think the problem is a nick in the face of the salt cell that the unions o-ring seals against, but I cant feel anything there so its not like a giant burr or anything. The hot side goes into the timer's N0-3 and common into com-1. Your thoughts? HELP!!! If the motor makes no noise at all, not even a peep, then its usually a power issue. 1. What could I be missing that would cause this? In my experience, a motor overheating is usually on its last legs what you could do is take it to an electric motor shop in town, and have them run it thru some diagnostics, should not be too expensive, but call first to check. Does the LED light turn off after 60 seconds? Reassemble pump in reverse order from above. PowerFlo LX is not a self-priming pump (Hayward PowerFlo II is self-priming), which means it has trouble lifting water vertically. Could also be a clog in the pipe. Can u shed any light on what might be the culprit? Hi, I have a H250PED2. The capacitor is like the battery in your car its needed to help get the pump up to speed (3200 RPMs) fast. All Does the panel just need to dry or did I cause possible damage? Settings while on Auto: 4200, 88, 26.8, 3.85, 91p, -4200, AI-0, R1.59, T3. Check the capacitor, for bulging, cracking, or melting. Ill look up the Drain King, is that something like a check valve? You can also pressurize the suction lines using a Drain King, connected to a garden hose and inserted at the skimmer, with a plug inside of the pump on the incoming pipe, or setting the multiport valve on closed. Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. New Assy is $500. The article says: to turn off the timer. Hope that helps! Hi Martha, open the air bleeder, perhaps there is a lot of air in the tank, drawn in by the pump. A less common cause of water out of the waste line is a broken Spring, under the handle, indicated by a floppy handle or difficulty turning the valve, I have a Hayward Super Pump it will run for about 1 to 2 hours and then it shuts off once it cools off for an hour or so I can turn it back on it will run again the water flow its good its just shuts off when it gets hot, Hi Steve; check that you have good air flow all around the pump, and above. And that the top gasket seats well into the groove in the filter body before putting the lid on. 58 amps! 908-355-7995. Air can enter pressure side if the water is not making it all the way to the top of the filter or chlorinator. },
It could be a problem the other way around, AG pumps cannot lift water vertically, so are not used on inground pools. fingers crossed, as we say. Something about level of placement of pump in relation to the water surface. I purchased a SP1580X15 Hayward pump July 2016 and began using it this year 2017. If the motor shaft and impeller is spinning freely (not clogged or bound-up), then remove the rear cover to the motor. Thanks! Use a Drain King to pressurize the pipe backwards, to remove such clogs. Some times it has overheated, it did re start, but I want to make sure that the motor is supposed to run continuously. Thanks in advance for any help. From the salt water panel into electrical panel/ timer there are three cables (ground, common and hot). I have a pre-2008 Northstar pump and it seems to be losing air seal. I first thought it might be the motor capacitor, new cap, problem still the same. i removed the filter fingers and cleaned numerous times. Another possible cause is that the impeller is clogged with very small debris. Also make sure that the stationary switch copper tabs are not fused together, and that it is centered on the centrifugal switch. Checked breakers etc tried again and it came onbut very loud. Came out tonight and flipped the switch and pump started. I have a maxi-flo 2 and it just stopped working. No need to look for a solution after the impeller, its always before, on the suction side. Now I turned the power off beacuse the circulation is not working and afraid the filter might blow up by the high pressure. Just replaced our pool pump, Hayward 1 hp self priming, super pump. "author": {
), or 4) loose suction side valves, I have a hayward 1081 century with 3/4 hp motor with top mounted capacitor. Sounds like maybe youve tried it both ways, at water level and below water level? I replaced the rod, and now my lid will not go down, the rod is the exact same as the other. Probably not cant think of another issue. There should be at least 12 of straight pipe before the switch. Used Cozzia Massage Chair, 2 yrs is unusual for bearings to go. The pump will always start in high speed, and stay in high speed for a few minutes after starting, to ensure full prime. After filter was fully re-assembled- pump would turn on. Hi Ann, in such cases, I would probably use a plumbers Pipe Wrench or very large Channel Pliers may work, or I have seen custom tools home-made from 24 wood, that fit over the ridge on the lid, with a few inches on either side to push on, or tap with a hammer. Features: Replacement for Hayward T-CELL-5, GLX-CELL-5-W and Aqua Trol Suitable for pools up to 20,000 gallons Comes with a 15 foot cord Clear housing for visual inspection of cell No need for re-plumbing, direct fitting threads Meets all original factory specifications Reverses polarity to automatically clean cell Hi Heidi, it sounds like maybe the plumbing could be reversed? hayward blue essence troubleshooting - Idahodownlow.com 7. inspect breaker, turn off breaker to pool from house main panel). If you program an incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. Hi probably not related to the vacuuming, but sounds like a motor problem. Hi Yolanda, also a great question first plug something else like a hair dryer or lamp into the outlet, to be sure its supplying 115V properly (or use a test meter). Fans of space opera and world-building fantasies will find this first book in the series compelling, concluding with a powerful vision of world-changing gods and attempts to free Eden from its curse that conclude in a cliffhanger for future books to explore. I assumed electrical issue but when I checked the voltage at the back of the motor and it was good I am at a loss. main drain and skimmer) to feed this thirsty pump. Today it completely shutdown at some point and tripped the breaker in the house. Hi Joe, the Perflex DE filter has a few dozen flex tubes covered in a mesh fabric. Well it so happens that I am having the exact same issue with the new cell. Is this rectifier bad? Could need cleaning. I then tried the pump at various speeds and it did not prime and circulate the water through the pool. If any of these readings are outside limits, replace motor. Not that I can think of, but something seems to be aerating your water? Second thing is to see if the Motor Shaft Spins Freely, rust can develop which can bind up a motor. Pump cavitation produces a lower pitched gravely sound, caused by the pump being starved for water from closed valves or clogged lines or clogged impeller. put in a new motor and had the old motor repaired. Although in low speed, chlorine is not generated so not sure why even run the low speed. If from the center of the lid around the stem, you can replace the two small stem o-rings, but sometimes the stem is worn down and needs replacement. Hi Leah, when the pump is barely pumping, the problem is either in front of the pump or after the pump. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Our pump is going through this one-off cycle similar to what others are describing. What can be the cause? Hi David, yes! the motor makes humming sound but nothing happened, then the motor became burning hot. I have a hayward pump installed as a new this March, 1.5 hp motor with a 23 inch filter to support a 12,000 gallons pool, it was working properly the first 3 months occasionally motor shut off and it wasnt by the breaker, since a week motor keep running only by 20 ,ins and suit off, touching the motor it is hot, I review filter pressure it is 15 psi, it is the same since installation. I have it set on a timer and when the pump comes on the flow rate is good but as the day goes on it becomes less and less. Hayward pumps come in a variety of horsepowers, voltages and speeds. Or backwash extra long, 4-5 minutes. Second possibility is the pump is too high above water level. I have a Hayward SP2607x10 pump with a Hayward C48k2n143B1 self priming super pump. Hi Donna, the screws that are removed to rotate are the long thru-bolts that run thru the motor, and are turned at the rear of the motor (spray with WD-40 first). Is there a resource I can look at to help understand the enter system, that is control by the Aqua Logic Power Panel. If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. stranger things backpack hot topic. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. Is the GFCI test button tripped? Don't stress! The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. Another check to do is to place the multiport valve on recirculate, which bypasses the filter, and will let you know for sure that the problem is in the filter sand. The high temp limit that is the pump motor as a thermal overload switch (located at 12 oclock in rear of motor), that will shut the motor down and prevent restart until the overload senses lower temps and resets itself, at which point the pump should turn on again, by itself. This could drain the pool down to the skimmer, or possibly much lower in some cases, so keep a close eye on any leak and look for signs of worsening. I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker. I used no lube on the gasket. It leaks where the seal plate connects to the pump/strainer housing. HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 This is wholesale site for our registered customers. Thoughts? I have a max-flo vs pump and it cant seem to stay at a high rpm for any long stretch of time when its sunny. I just purchased a brand new Hayward Super Pump 1.5HP for my pool that is being renovated. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. Old broken wires inside of the conduit could be the problem. News Reporter Reveals On Live TV That Shes Been Secretly Recording . When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. Hi the strainer housing must need to be tightened up. It was wired for 230 but only had 115 going into it (we realized this after we had a pool guy come and see it) for a long time. If they are within range, replace drive. Is there a break in period for the unit or do I need to call the technician? Could also be low water level in the pool, or a stuck skimmer weir, blocking water flow. Hi Wilson, I cant find any info on that error message paused / valve change but it would sound like it thinks that either a filter valve or directional valve is being turned, so it has paused water flow. HI, that is usually a weak motor capacitor, which is a battery used to help the motor get up to 3450 RPM quickly. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. I replaced my old hayward maxflow pump with the new variable speed sp2670020vsp. If thats not the issue, is the pump sized correctly for the filter, and not under/over sized? Worn bearings can also create enough heat to trip the switch. If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. Replace with the exact same MFD number printed on the capacitor. I had my Hayward pool/spa installed about 4 years ago. Capacitors are cheap to replace, order the exact MFD number, printed on it, or you can pick up local at a motor shop. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. Checked to make sure nothing was blocking it. When corrected, control will run blower for 5 s then automatically restart after 2 minutes. And you cant rule out a problem with the circuit board either. It doesnt mean it is ready to go at 230. Hi Rodney, well the Green wire should be ground, so that eliminates one choice. Shut off power at the breaker to all pool equipment I have 2 pumps, Ecostar for pool and Tristar VS for my waterfall, the pool pump is working fine, the Tristar will not come on, when I use my Omnilogic app or or the panel to turn on it just says-paused/valve change, but there is no valve change going on-having a Memorial Day party this Saturday and getting a bit freaked out, I have tried calling support, but they put me on indefinite hold, and I cant seem to get in touch with pool company-please help. I added new wire and plug end but when I plug it in it trips the breaker. Hi Dave, we are replacing a Hayward superpump 1.5 horsepower with the same pump. or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch.